Securitex Marine Specialized Equipment Development Division






Securitex DMAS Series A110/24.238.2006.V1
[Dead Man Alarm System]
Securitex
DMAS
Series A110/24.238.2006.V1 is developed to ease the
installation on vessel as this unit come with built-in 110VAC power supply step
down to 24VDC for the use on the 24VDC motor horn siren
What is Securitex DMAS? DMAS is a programmable countdown
timer system that is preprogrammed at a certain time interval. This timer will
countdown and upon time –up the Siren connected to the DMAS will sound
reminding the Security personnel to go for their rounds. (The more complex
system can be interface to system than can activate distress signal and event
reporting etc OPTIONAL)
System
works as follows:
The system
is preset at default 15 minute. Upon the 15 minute is up the timer 1 (T1) will
kick in and activate the relay to trigger the baby siren. If the monitoring personnel
do not reset the baby siren after say 10 minute (time is programmable), the
second built-in timer (T2) will cut in and activate the 2nd relays to trigger
the master horn siren. In the event the baby siren trigger and the monitoring
personnel reset it, the system will automatically reset back to 15 minutes and
re-count again. If after 10 minutes are up and the baby siren is not reset the
master horn siren will trigger, in this instance to reset the system just press
any reset button and the system will reset back to the original preset timing
again.
Securitex Dead Man Alarm System (DMAS Series A110/24.238.2006.V1) detail system operation
When power
is turn on, the DMAS will activate with T1 indicate 0015 (15 minutes).
Immediately the T1 timer will count down from 0015 to 0000. At 0000/9999 the T1
(LED will turn on and R1 will activate. This R1 activation will trigger the
Alarm 1 (Baby siren). If at anytime before the T1 time is up and the reset
button is press, the T1 will reset back to 15 minutes and continue the T1 count
down as indicated above. However if the reset button is not press T2 board will
activate and display 0010 (10 minutes) and start counting down to 0000/9999. At
this point the T2 (LED will turn on and R2 will activate this will trigger the
Alarm 2 (Master horn siren). Till the reset button is press, both alarms will
continue to sound.
To change the Count-down timing for Timer
1 (T1)
a.
Press the (T1) SW1 for 1 second (the
first digit of the 4 digit 7 segment display will blink).
b.
Press SW2 to move the digit forward
to the digit you want to change.
c.
Press
SW3 to decrease the digit and press SW4 to increase the digit
d.
Exit programming by pressing SW1
after time set.
Example:
0015 indicated 15 minute
To change the Count-down timing for Timer
2 (T2)
Press
and hold Button 6 (BU 6).
(T2)
Timer board will be lighted up and indicate 0010.
Continue
to hold Button 6 when programming (T2)
e.
Press the (T1) SW1 for 1 second (the
first digit of the 4 digit 7 segment display will blink).
f.
Press
SW2 to move the digit forward to the digit you want to change.
g.
Press SW3 to decrease the digit and
press SW4 to increase the digit
h.
Exit programming by pressing SW1
after time set.
Example:
0010 indicated 10 minute
Note the
T1 and T2 board.
When the
Time out is up and the system is not reset, the T1 and T2 board will switch to
0000. After 1 minute the T1 and T2 will switch to 9999 and count down from 9999
to 9998 to 9997 etc…… this is normal and the figure indicate the total time the
siren had sounded.
The Default setting for [T1 is 15 minute] & [T2 is 10 minute]
Note:
T2 will only
start counting down if T1 is not reset after 15 minute
|
Technical Specifications (Securitex DMAS Series A110/24.238.2006.V1) |
||
|
Description |
Specification |
Application |
|
Supply voltage (Switching Power supply) |
110VAC |
|
|
Supply current |
40mA to 80mA |
|
|
Relay 1 |
24VDC |
For baby siren |
|
Relay 2 |
24VDC |
For Master siren
|
|
Relay switching capability |
Up to 28VDC and 12Amp |
Option for dry contact by jumper |
|
Relay 1 & 2 activated output (Voltage) |
24VDC
|
|
|
Reset button 1 |
Fitted on the DMAS |
Reset button provided on system. |
|
Reset button 2 |
Connector provided (only) |
Not provided |
|
Reset button 3 |
Connector provided (only) |
Not provided |
|
Gross Dimension of DMAS |
250mm X 175mm X 75mm |
|
For more information or specifications on Securitex DMAS please contact:
Singapore Sales office:
Securitex Electronic Systems Engineering
Block 9010 Tampines St 93 #04-145
Tampines Industrial Park A
Singapore 528844
Tel: 67852171 Fax: 67863351
Attn: Mr. David Tan
Download the catalogue: Click Here
Securitex Electronic Systems Engineering
Block 9010 Tampines St 93 #04-145 Tampines Industrial Park A Singapore 528844 Tel: 65-67852171 Fax: 65-67863351